STC-3028 220V Temperature and Humidity Controller with Integrated Sensor For Incubator COM52 R28

(1 customer review)

Fr15,000

The STC-3028 is a popular digital thermostat that can be used to control the temperature of a variety of appliances, such as incubators, fermentation chambers, and aquariums. It has a wide temperature range of -20°C to 80°C and a high accuracy of ±1°C.

In stock

SKU: SCT30482 Categories: ,

Description

The STC-3028 is a popular digital thermostat that can be used to control the temperature of a variety of appliances, such as incubators, fermentation chambers, and aquariums. It has a wide temperature range of -20°C to 80°C and a high accuracy of ±1°C. The STC-3028 also features a dual display that shows both the current temperature and the set temperature.

The STC-3028 is easy to use and can be programmed with just a few buttons. It has two output modes: heating and cooling. In heating mode, the STC-3028 will turn on a heating device when the temperature falls below the set point. In cooling mode, the STC-3028 will turn on a cooling device when the temperature rises above the set point.

Here’s a guide on how to program the STC-3028 Temperature Controller:

Key Instruction

  • Aideepen-STC-3028-Temperature-Humidity-Controller-fig- (3)increase the value of the start temperature
  • Aideepen-STC-3028-Temperature-Humidity-Controller-fig- (3)decrease the value of the stop temperature
  • Aideepen-STC-3028-Temperature-Humidity-Controller-fig- (4)increase the value of start humidity
  • Aideepen-STC-3028-Temperature-Humidity-Controller-fig- (4)decrease the value of stop humidityAideepen-STC-3028-Temperature-Humidity-Controller-fig- (2)

Key Operation Instruction

Temperature setting:

  • In normal working status, the left led displays the real-time temperature. Press theAideepen-STC-3028-Temperature-Humidity-Controller-fig- (3) key once. Red led display start temperature. Press theAideepen-STC-3028-Temperature-Humidity-Controller-fig- (3) key once. Red led display stop temperature.
  • Hold theAideepen-STC-3028-Temperature-Humidity-Controller-fig- (3) key for 3s. led flash. Press theAideepen-STC-3028-Temperature-Humidity-Controller-fig- (3) orAideepen-STC-3028-Temperature-Humidity-Controller-fig- (3) to change the start temperature.

    Ezoic

  • Hold theAideepen-STC-3028-Temperature-Humidity-Controller-fig- (3) key for 3s. led flash, press,Aideepen-STC-3028-Temperature-Humidity-Controller-fig- (3) orAideepen-STC-3028-Temperature-Humidity-Controller-fig- (3) change stop temperature.

Humidity setting:

  • In normal working status, the right blue screen displays real-time humidity. Press theAideepen-STC-3028-Temperature-Humidity-Controller-fig- (4) key once. The Red led display starts humidity. Press theAideepen-STC-3028-Temperature-Humidity-Controller-fig- (4) key once. Blue led display stops humidity.
  • Hold theAideepen-STC-3028-Temperature-Humidity-Controller-fig- (4) key for 3s. led flash, press,Aideepen-STC-3028-Temperature-Humidity-Controller-fig- (4) orAideepen-STC-3028-Temperature-Humidity-Controller-fig- (4) change the start temperature.
  • Hold theAideepen-STC-3028-Temperature-Humidity-Controller-fig- (4) key for 3s. led flash, press,Aideepen-STC-3028-Temperature-Humidity-Controller-fig- (4) orAideepen-STC-3028-Temperature-Humidity-Controller-fig- (4) change stop temperature.

Operation Instruction

Cooling mode:
When the set start temperatureAideepen-STC-3028-Temperature-Humidity-Controller-fig- (5) stops temperature, the controller will work in cooling mode. You can use the cooler as a load. For example, set the start temperature to 35 C, and the stop temperature to 32 C. Cooler works when the temperatureAideepen-STC-3028-Temperature-Humidity-Controller-fig- (5) is 35 C, and Cooler stops when the temperatureAideepen-STC-3028-Temperature-Humidity-Controller-fig- (6) is 32 C.

Heating mode:

When set start temperatureAideepen-STC-3028-Temperature-Humidity-Controller-fig- (5) and stop temperature are, the controller will work in heating mode. You can use the heater as a load. For example, set the start temperature to 45 C, and stop the temperature to 60 C. Heater stops when the temperatureAideepen-STC-3028-Temperature-Humidity-Controller-fig- (5) 60’Cheater works when the temperatureAideepen-STC-3028-Temperature-Humidity-Controller-fig- (6) 45C.

Dehumidification mode:
When set start humidity stop humidity,Aideepen-STC-3028-Temperature-Humidity-Controller-fig- (5) the controller will work in dehumidification mode. You can use a dehumidifier as a load. For example, set the start humidity 35%RH, and stop humidity to 156RH. Dehumidifier work when humidity isAideepen-STC-3028-Temperature-Humidity-Controller-fig- (5) 35%RH, Dehumiditifier stops when humidity isAideepen-STC-3028-Temperature-Humidity-Controller-fig- (6) 15%RH.

Humidification mode:
When set start humidityAideepen-STC-3028-Temperature-Humidity-Controller-fig- (5) stop humidity, the controller will work in humidification mode. You can use a humidifier as a load. For example, set the start humidity 45%RH, and stop humidity 60%RH. Humidifier stops when the humidityAideepen-STC-3028-Temperature-Humidity-Controller-fig- (5) 60’C and Humidifier works when the humidityAideepen-STC-3028-Temperature-Humidity-Controller-fig- (6) 45C.

Reset:
In normal working status, holdAideepen-STC-3028-Temperature-Humidity-Controller-fig- (3) and,Aideepen-STC-3028-Temperature-Humidity-Controller-fig- (4) the two screens will display 888 to reset the controller.

Temperature and Humidity Calibration:

  • In normal working status, holdAideepen-STC-3028-Temperature-Humidity-Controller-fig- (3) andAideepen-STC-3028-Temperature-Humidity-Controller-fig- (3) for 2S to enter calibration mode of temperature. Presslorto value between -30-30
  • In normal working status, holdAideepen-STC-3028-Temperature-Humidity-Controller-fig- (4) andAideepen-STC-3028-Temperature-Humidity-Controller-fig- (4) for 2S to enter calibration mode of humidity. The PressAideepen-STC-3028-Temperature-Humidity-Controller-fig- (4) orAideepen-STC-3028-Temperature-Humidity-Controller-fig- (4) set a value between -30-30
  • For example, the tested temperature display 25C, but the real temperature is 30 C, If we set the value 5, the tested temperature will change to display 30 C(25C+5 C). If we set the value to -5, the tested temperature will change to display 20C(25C-5C).

 

Package includes:
1 x STC-3028 220V temperature humidity controller
1 x Integrated sensor